Blood Bank Refrigerator Manufacturer in India
Blood Bank Refrigerator Manufacturer in India Make Blood bank refrigerator is designed to be durable , highly consistent and has a powerful design and construction. Created with robust housing and high quality component , the hamco make blood bank refrigerator guarantees reliability and precision for all Blood banking and processing applications.
- Temperature range : 2 to 8 degree C.
- Temp. controller : Microprocessor based PID control with auto tune facility.
- Temperature sensor : RTD Pt 100.
- Temperature display : Digital LED 3 ½ digit.
- Chamber illumination : Floroscent Light with door switch.
- Cooling : CFC free compressor utilising R 134a eco friendly refrigerant , with condenser , motor and relay .
- Air circulation : With flange motor and blower.
- Feet : Castor wheels.
- Trays : SS wire mesh , Heavy duty.
- Construction : Double walled with poly urathene ( PUF) insulation provided with outer full length glass
- Viewing door with locking arrangement.
- Double walled , gap between walls filled with PUF Insulation.
- Standard Model : Stainless steel Mirror polished chamber and heavy guage Powder- coated CRC exterior.
- GMP Model : Stainless steel Mirror polished chamber and exterior of dull finish stainless steel.
- 3” Thick CFC Free Puff Insulation.
- Stainless steel Trays. Adjustable Tray Height adjustment.
- Unit Mounted on castor wheels with front lock arrangement.
- Microprocessor based PID temp. controller with auto tune facility for precise control of temperature
- Temp. Sensor : PT- 100
- Recorder data bank to store and print set values , process values , date and time of master controllers with variable print time intervals ( Optional)
- PC Interface communication card with RS 485 for temperature and humidity control system ( Hardware only) ( optional)
- Over heat temperature cut off .
- Electrical overload compressor cutoff.
- Time delay for compressor switch on.
- Electrical short circuit breaker.
- Room temperature around machine preferably at 25 degree C.
- Stabilised input voltage of 230V Ac, 50 Hz, 20 Amps.
- Water drain line with ½” Nozzle to be provided at floor level.
- 21 CFR Part 11 compliant software with audit trial ( who did what and when is recorded)
- Multilevel Passwords.
- Data storage device has online and offline capabilities.
- Multi chamber data acquisition on single software.
- Tabular and graphical report, alarm deviation report.
- Mean Kinetic temperature report and alarm deviation report.
- Audit trial report.
- Attractive reports and graphs.
- Alarm report.
- Time synchronisation.
Ordering Information:
MODEL NO. | CAPACITY | DIMENSION IN CMS | SHELVES | WT IN KG | POWER | |||||
---|---|---|---|---|---|---|---|---|---|---|
Standard | GMP | Cu. Ft | Litres | Chamber | Over All | – | Unit | Packed in wooden case | VAC Hz | Watts |
HAMCO46S -3 | HAMCO46 G-3 | 3 | 90 | 45x45x45 | 60x95x110 | 2 | 110 | 165 | 230,50 | 1500 |
HAMCO46 S-4 | HAMCO46 G-3 | 4 | 120 | 45x45x60 | 60x95x125 | 2 | 150 | 225 | 230,50 | 2000 |
HAMCO46 S-8 | HAMCO46 G-8 | 8 | 200 | 60x60x60 | 80x110x125 | 2 | 220 | 300 | 230,50 | 2500 |
HAMCO46 S-12 | HAMCO46 G-12 | 12 | 324 | 60x60x90 | 80x110x155 | 3 | 230 | 320 | 230,50 | 2500 |
HAMCO46 S-16 | HAMCO46 G-16 | 16 | 450 | 60x60x125 | 80x130x175 | 4 | 340 | 430 | 230,50 | 4000 |
HAMCO46 S-21 | HAMCO46 G-21 | 21 | 600 | 60x80x125 | 80x130x195 | 5 | 365 | 465 | 230,50 | 4000 |
HAMCO46 S-28 | HAMCO46 G-28 | 28 | 800 | 80x80x125 | 100x130x210 | 5 | 390 | 500 | 230,50 | 4500 |
HAMCO46 S-34 | HAMCO46 G-34 | 34 | 1000 | 80x80x155 | 100x130x220 | 5 | 430 | 525 | 230,50 | 4500 |