- What is Walk In Cooling chamber :
Walk in cooling chambers are specially designed equipment for the testing of products and also to test Microbiology study, Storage, environmental test , Research and development etc which enables you to tweak parameters like temperature to conduct a thorough check over varied conditions.
- Use of the Walk in Cold room :-
The walk in cold room help for the testing of drugs in varied conditions of temperature,. Walk in cold room are also used to check for how long the product will be efficient to use.
- Working principle of Industrial walk in cooler :
The Industrial walk in cooler consists of motor and blower arrangement for air circulation to achieve uniform temperature across the working area. It is a well-insulated double walled chamber and can maintain the temperature as per the set point on the controller within the specified limits.
- What is the standard Walk in cooling room for Lab follows:
ICH Guidelines , WHO Guidelines, cGMP guideline for shelf life study.
- What is the difference between cooling chamber and walk in cooling chamber?
- In cooling chamber you need to stand in front of the chamber and open the door to load or unload the sample .
- In walk in cooling chamber , you open the door , go inside the chamber and walk through the chamber to load, unload or change the sample and during this you can close the door.
- Usually walk in cooling chamber is bigger version of the cooling chamber.
- Normal cooling chamber comes around max size upto 3000 Litres. Hamco Walk in cooling incubator starts from 4000 Litres upto 100000 Litres.
- Objective of Pharma walk-in cooling chambers
The primary objective of a pharma walk-in cooling chamber is to provide a controlled low-temperature environment for the safe storage, testing, or preservation of temperature-sensitive products. These chambers are especially vital in industries like pharmaceutical, biotechnology, food, chemical, and research laboratories.
- What is the key application of Large walk in cold storage :
1.Temperature Control & Stability:
Walk-in refrigeration chamber Maintain a constant and uniform low temperature (commonly between 2C to 8C or as per requirement) to ensure product stability and integrity.- Storage of Temperature-Sensitive Products:
Walk-in refrigerator Ideal for bulk storage of materials such as:
- Vaccines
- Drugs
- Biological samples
- Chemicals
- Food items
- Compliance with Regulatory Standards:
Walk-in temperature controlled chamber Ensures compliance with standards like GMP, WHO, FDA, etc., which require specific temperature-controlled storage. - Prevent Product Degradation:
Walk-in cooling unit Reduces the risk of spoilage, microbial growth, or chemical breakdown due to high temperature. - Efficient Space Management:
Walk-in cooler for pharmaceutical use Offers large-volume storage with shelving and easy access inside the chamber, suitable for industrial-scale operations. - Testing Under Controlled Conditions:
Walk-in cooling chamber Used in stability testing, shelf-life studies, and climatic simulations for pharmaceutical and biotech R&D.
- GMP Compliant Walk-in cooling chamber Storage Conditions :
Conditions Name Storage temperature (C) Microbiology 2.0 C +/- 2 C Microbiology 5.0 C +/- 2 C Microbiology 8.0 C +/- 2 C - Why 21 CFR Software compliant walk in cooling chamber require?
The major challenges that the auditor has that all the data submitted of the testing should be authentic and non tempered. This will only possible if it is 21 CFR Complied data is there. Thats why it is important to have Walk in incubator with 21 cfr complied compliance.
- What is DQ,IQ,OQ,PQ documents?
Normally Manufacture gives the User set of documents or say checklist kind of documents which on completition of doing will check the Walk in incubator thoroughly on all the parameters.
Terminology Full Form Use DQ Design Qualification This confirm that How de design the chamber and why certain component has been selected. IQ Installation Qualification This confirm How to Install the equipment by checking all the component Make, sl No and certificate, Preinstallation requirement and Utilities. OQ Operational Qualification This confirm the operation wise checking of all the paramenter of the equipment. PQ Performance Qualification This confirm the performance qualification of the stability chamber. - What is Validation of the walk in cooling chamber and its protocol?
Validation means checking the performance of the chamber on accuracy and uniformity by placing sensors at different location for specified time interval and checking report for its Confirmatory. Normally Validation will be Onsite ( Checked by the Manufactory on its location ) and offsite at Buyer location. It will be empty, Part load and Full Load depending on the validation protocol.
- Why Hamco?
Hamco has reach experience in designing and manufacturing stability chamber since last 15 years. We are having more than 1000 successful installation in India and globe. We are strong service support with In house manufacturing and software design capabilities.
- Hamco is Leading Manufacturer of Walk in cooling chamber in india
- Hamco is exportor of walk in cooling chamber in india
- Hamco is walk in cooling chamber supplier in india
- Hamco is Manufacturer of Large walk in cold room in india
- Hamco is Manufacturer of Pharma walk-in cold room in india
- Hamco is Manufacturer of Walk-in refrigerator
- Hamco is Manufacturer of walk in pharma refrigerator.
- What are the other names walk in cooling chamber known.
- Walk-in cooling chamber
- Walk-in cold room
- Industrial walk-in cooler
- Walk-in cooling room for lab
- Pharma walk-in cooling chamber
- Large walk-in cold storage
- Walk-in refrigeration chamber
- Walk-in temperature controlled chamber
- Walk-in cooling unit
- Walk-in cooler for pharmaceutical use
- Walk-in cooling chamber for pharmaceutical storage
- Energy efficient walk-in cold room
- Walk-in cooling chamber with data logger
- GMP Compliant walk-in cooling chamber
- Laboratory walk-in cold chamber with PLC
- Custom walk-in cooling chamber for stability testing
- Walk-in cooler with temperature and humidity control
- Walk-in cooling chamber with automatic defrost
- Best walk-in cooling chamber for Vaccine storage
- Walk-in cooling chamber for food and pharma industry
- Walk-in refrigerator
- Walk-in freezer chamber
- Cold storage chamber for pharma
- Stability chamber walk-in type
- Controlled environment chamber
- Walk-in climate chamber
- Features of Hamco Walk in cooling chamber.
Hamco is making below said Table series walk in cooling chamber
Features What it Includes Benefits Walk in cooling Incubator Asthetically look chamber with racks and trays Precisely temperature controlled chamber 7 Capacitance type display HMI Big bright display with data logging facility of 30000 data Easily visible and can save data upto 1 year if the logging interval is 15 Min Standby Refrigeration system One Main refrigeration system and one standby refrigeration system. If one system fail , it automatically switch to ther system. Which gives time to repair system without breakdown. Scanner 8 channel (SCN-8) 8 Temp sensor placed at different location of the chamber Which monitor the air flow and auto validate the chamber. Alarm Transmission system - External Hooter
- Mobile alert.
- Email Alert.
First alarm will come to display and after 2 Min it will horn external hooter placed at qc room or security and if not attended after 15 min it shoot the alarm on mobile sms and than after 30 Min to email. Authorised door access Biometric door access Just place he figure and open the door. No need to put the password and remember password. - Hamco Walk in cooling chamber Unique Features.
- CE Certified chamber with IP 22 protection safety.
- Precise control of Temperature .
- 7 HMI+PLC with capacitance type of display for better performance and monitoring.
- Door Access System ( DS ) : Authorised door access system to allow only authorized person to open the door and maintain door access report with reason.
- Stand by Refrigeration (S.REF1) : Standby refrigeration system with auto changeover facility.
- Scanner ( SCN 8) : 8 Temp sensor for auto validation of the chamber 24 X 7.
- 21 CFR Software ( SOFTW21) : Web based 21 cfr software with multi PC login across the Network with auto backup , data archive facility and many other facility. 18 type of report generation . Multi level user access with password expiry.
- Mobile alert ( GSM ) : Mobile alert system for alarm transmission by mobile sms on the user defined selected alarms.
- E-mail Alert ( EMAIL ) : E-mail alert system for alarm transmission by E-mail on the user defined selected alarms.
- External Hooter ( EX.HTR) : External Hooter which placed on security or QC room horns the buzzer on alarm generation.
- Mobile App (MA) : Mobile app having authorized access by permission giving to server database access to see the chamber live from anywhere through mobile app.
- Complete with DQ,IQ,OQ,PQ of the equipment as well as software
- Validation cycle as per client protocol.
| CERTIFICATIONS
|
OUR CHAMBERS ARE CE Certified Chambers . We as company is ISO 9001:2008 Certified Company.
|
| FEATURES | Consist of Chamber (Hamco 66 SERIES) + Ethernet Based Connectivity + HMI PLC ( 7 Touch Screen PLC Display ) + SOFTW-21 (Web browser based Software Part 11 21 CFR ) +BDS (Biometric door access system) + SCN-8 ( 8 Temp) + Stand By Refrigeration System(S.REF1) + Mobile Alert System (GSM) + Email Alert Facility + E Report Facility +VAL ( Validation). |
| RANGE/ ACCURACY / UNIFORMITY | Temperature Range 2C to 8C , Temperature Accuracy +/- 1C , Temperature Uniformity : +/- 2C . |
|
CONSTRUCTION GMP MODEL |
Double walled , gap between walls filled with PUF Insulation. Inner Body made of SS 304 Mirror Finished, Outside SS 304 Matt Finished. Double door : Inner full Viewing door and outer door insulated with lock and key arrangement. 50mm Validation Port with silicon rubber seal to insert sensor for validation purpose. 3 Thick CFC Free Puff Insulation. Stainless steel Trays. Adjustable Tray Height adjustment. Unit Mounted on castor wheels with front lock arrangement. Stainless steel Rod Trays. Adjustable Tray Height adjustment.
|
| LIGHTING | Floroscent Light are provided , which automatically On when we open the door. |
|
CHAMBER PRINCIPLE |
Air circulation by Circulation Motor & Fan will continuously sucks the air from the chamber and Passes it through Air heater, Evaporator and through it back to chamber and same air will be recirculated to achieve desired Temperature stability inside chamber. Our design reduces the power consumption by 50% . |
|
ICH GUIDELINES |
Fully Suitable to carry out Stability Studies For Conditions Such As :
Also Suitable for Low temperature ICH conditions Laid out for drug Products packed in Semi-Permeable Containers
|
|
APPLICATIONS |
Application includes Microbiology , ARD Labs , Packing , Life science , Medical Storage & R&D activity. |
|
HEATING & COOLING SYSTEM |
Interior Illumination for working Area. There will be two nos of blower from 450 Ltr Onwards. |
|
DQ,IQ,OQ,PQ |
To Help the customers to meet current regulatory requirements for the equipment , Hamco can provide DQ,IQ,OQ,PQ Protocols. This Protocol ensures that the system is properly installed, Operating as per our recommendations , Adequately documented and controlled according to regulatory requirements.
Calibration certificate & Test certificate of critical components along with Operation , Maintenance Manual, Wiring diagram , chamber diagram, sensor position diagram provided. Operation Training of the instruments along with software installation and software Training is part of our Operation Qualification. |
|
VALIDATION & CALIBRATION |
Calibration of chamber is provided with Treacability against standard used.
Hamco will give one cycle 24 hours Validation report offsite . ( Validation is putting temp sensors at different position in the chamber confirming Uniformity at different places in the chamber. ) |
| TEMPERATURE & HUMIDITY SENSOR |
|
|
DISPLAY |
HMI Display is 7 Color Touch Screen Display of Delta Make with display shows
|
| DOOR ACCESS SYSTEM
(DS) |
Limited Door access through Password protection. The person with Authorised password can only open the door with reason . In software we get the door access report which shows who open the door , when & for what reason with time stamp. |
| BIOMETRIC DOOR ACCESS SYSTEM
(BDS) |
Limited Door access through Fingerprint authentication. The person with Authorised fingerprint can only open the door with reason . In software we get the Biometric door access report which shows who open the door , when & for what reason with time stamp. |
| AUTO SENSOR CHANGEOVER
(SAFETY-1) |
In the case of Master Temp sensor Fails , it switch over to Standby Temp Sensor.
|
| STAND BY COOLING SYSTEM
(S.REF 1) |
In case of Failure of Comp 1 , it switch over to Comp2 , thus reduces down time)
|
| TEMPERATURE & HUMIDITY SCANNER
(SCN 8) |
8 Temp sensor including one Master Sensor Placed at different Position in the chamber to Study the distribution of conditions in the different locations of the chambers and thus helps in Auto- Validate the chamber and helps in easy detection of Drift in the sensor |
| MOBILE ALERT (GSM) | You will get SMS Alert on critical utility paramenters like Temp High & Low Alarm, Low water Level, Power Fail etc as alarm transmission device. |
| EMAIL ALERT (EMAIL) | You will get Email Alert on critical utility paramenters like Temp High & Low Alarm, Humidity High & Low Alarm, Low water Level, Power Fail etc as alarm transmission device. |
| EXTERNAL HOOTER
(EX.HTR) |
In case of any Alarm External hooter will horn the buzzer and give the pop up indication and this has to be mounted on security room for qc room as per buyer protocol.
The cabling from external hooter to chamber will be at buyer scope.
|
|
CONTROLLING SYSTEM |
The controlling system is Fully PLC Based , It consist of HMI Display , PLC Digital & Analogue cards, Relays, Contactors, Overload Trip devices, MCB. Separate Connection for Main & UPS ( UPS will be on Buyer Scope). This helps in recording the chamber conditions even during Power fail and capture the event of Power Fail & Resume during the conditions. The control panel has below features.
Mins , it can save more than one year data.
|
|
SAFETY |
Temperature Safety :-
Human Safety :-
Sensor Safety :-
|
|
ALARM GENERATION |
Audio & Visual Alarms are generated for :
|
| PC COMMUNICATION (ETH-1) | Ethernet Based Connectivity for High speed Data transmission. |
|
SOFTWARE WEB 21 |
It is Web Browser Based Software( You can access the software from any PC Connected in LAN to Server PC ). Having Below said Features .
|
| Product Display video Link | https://youtu.be/AooJJAbesQ8 |
Ordering Information:-
| Model no. | Standard | Gmp | Capacity | Dimension in cms | Tray | |||||
| Litres | Cu. Ft | Chamber size in mtr (hwd) | Overall size in mtr (hwd) | Qty. | Tray size in mm | |||||
| 1 | Hamco62s -190 | Hamco62g-190 | 190 | 5400 | 2.01.362.0 | 2.161.522.16 | 24 | 870300 | ||
| 2 | Hamco62s -230 | Hamco62g-230 | 230 | 6400 | 2.41.362.0 | 2.561.522.16 | 32 | 870300 | ||
| 3 | Hamco62s -280 | Hamco62g-280 | 280 | 8000 | 2.02.02.0 | 2.162.162.16 | 24 | 870600 | ||
| 4 | Hamco62s -340 | Hamco62g-340 | 340 | 9600 | 2.42.02.0 | 2.562.162.16 | 32 | 870600 | ||
| 5 | Hamco62s -428 | Hamco62g-428 | 428 | 12000 | 2.42.02.5 | 2.562.162.66 | 48 | 725600 | ||
| 6 | Hamco62s -530 | Hamco62g-530 | 530 | 15000 | 2.42.52.5 | 2.562.662.66 | 48 | 725800 | ||
| 7 | Hamco62s -640 | Hamco62g-640 | 640 | 18000 | 2.42.53.0 | 2.562.663.16 | 48 | 900800 | ||
| 8 | Hamco62s -1070 | Hamco62g-1070 | 1070 | 30000 | 2.42.55.0 | 2.562.665.16 | 80 | 920800 | ||
| 9 | Hamco62s -1785 | Hamco62g-1785 | 1785 | 50000 | 3.04.24.0 | 3.164.364.16 | 140 | 870600 | ||
| 10 | Hamco62s -2857 | Hamco62g-2857 | 2857 | 80000 | 3.04.85.56 | 3.164.965.72 | 180 | 870600 | ||