- What is the HALT AND HASS Chamber?
Ans :- A Halt and hass chamber is a controlled-environment enclosure used to expose products, materials, or components to specific temperature and sometimes humidity conditions for a set period of time. Its main purpose is to stabilize a samples physical and chemical properties before testing, manufacturing, or storage, so results are consistent and meet industry standards.
- What is the use of HALT HASS Testing equipment ?
HALT & HASS testing equipment are used to improve the reliability, durability, and quality of electronic and mechanical products by exposing them to controlled extreme environmental stresses.
- Common types of Halt and hass Test chamber?
Some common types of Halt and hass Test chamber include:
- Temperature test chambers: These chambers control the temperature within a specific range,
allowing products to be tested under extreme cold or hot conditions.
- Application of Halt hass Test system?
Ans :- Halt and hass Test system also known as Halt and hass Test chambers have a wide range of applications across various industries. Some common applications of environmental thermal chambers include:
- Aerospace and Defense: Reliability Test chamber are used to test the performance and durability of aircraft components, satellites, missiles, and other aerospace equipment under extreme temperatures, high altitudes, humidity, and vibration.
- Automotive Industry: Halt chamber are employed to evaluate the performance and reliability of automotive components, such as engines, electronics, batteries, and tires, under different environmental conditions, including temperature, humidity, and thermal shock.
- Electronics and Semiconductors: Hass chamber are used to assess the reliability and functionality of electronic devices, circuit boards, integrated circuits (ICs), and other electronic components under varying temperature, humidity, and vibration conditions.
- Pharmaceuticals: Highly accelerated life test chamber are utilized to test the stability and shelf-life of pharmaceutical products, drugs, and vaccines under controlled temperature and humidity conditions to ensure their efficacy and safety.
- Telecommunications: Halt test chamber are employed to test the performance of telecommunications equipment, such as routers, switches, and antennas, under different temperature, and vibration conditions to ensure their reliability and functionality.
- Material Testing: Hass test chamber are used to evaluate the behavior and properties of materials, such as metals, plastics, composites, and polymers, under specific environmental conditions, including temperature, humidity, and thermal cycling.
- Energy and Power Systems: Halt and hass chamber are utilized to assess the performance and reliability of batteries, solar panels, wind turbines, and other energy storage and generation systems under different temperature and humidity conditions.
- Consumer Electronics: Halt and hass chambers are employed to test the durability and functionality of consumer electronic products, including smartphones, laptops, appliances, and wearables, under various environmental conditions.
- What are the ranges of Halt and Hass chamber ?
Ans:- Thermal chamber known as Thermal Test chamber come in various sizes and configurations to accommodate different testing requirements. The size and range of an Thermal chamber can vary significantly based on the specific application and industry. However, here are some general ranges of Thermal chambers:
- Temperature Range: Thermal chambers can simulate temperatures ranging from extremely low temperatures, such as -70C (-94F) or lower, to high temperatures exceeding 190C (374F) or even higher in specialized chambers. Some chambers may have a limited temperature range, while others offer a wide range of temperature control.
- What are the benefit of Halt and Hass Test Chamber ?
Ans :- There are several benefits to using an Thermal chamber in various industries and testing applications:
- Product Reliability and Performance: Halt and Hass Test chamber allow manufacturers to evaluate the reliability, performance, and durability of their products under controlled and repeatable environmental conditions. By subjecting products to simulated extreme temperatures, humidity, vibration, and other stresses, potential issues or weaknesses can be identified and addressed before the products are released to the market. This helps ensure that products can withstand real-world environmental conditions and perform as intended.
- Quality Control: Halt and Hass Chamber helps in maintaining high quality standards for products. By subjecting products to rigorous environmental conditions during testing, manufacturers can identify any potential defects, malfunctions, or performance issues early in the development or production process. This enables them to make necessary improvements, modifications, or design changes to meet quality requirements and deliver reliable products to customers.
- Compliance with Standards and Regulations: Many industries have specific standards and regulations that products must meet to ensure safety, reliability, and compliance. Temperature test chambers enable manufacturers to test their products against these standards and regulations. By replicating the required environmental conditions specified by regulatory bodies, manufacturers can demonstrate the compliance of their products and gain necessary certifications or approvals.
- Cost and Time Savings: Halt and Hass Chamber testing in a controlled chamber allows for accelerated testing cycles and shorter development times. By subjecting products to accelerated aging, thermal cycling, or other stress tests, manufacturers can simulate years of real-world use in a matter of days or weeks. This helps in identifying potential failures or weaknesses early in the product lifecycle, reducing the need for costly field failures or product recalls. Additionally, by identifying and addressing issues early, manufacturers can avoid costly redesigns and modifications later in the production process.
- Research and Development: Halt and Hass Test Chamber are valuable tools for research and development purposes. They enable scientists, engineers, and researchers to study the effects of different environmental conditions on materials, components, and systems. This helps in advancing technology, improving designs, and developing new products that can withstand challenging environments.
- Customer Satisfaction: By subjecting products to comprehensive thermal testing, manufacturers can enhance customer satisfaction by delivering reliable, high-quality products that perform well under various conditions. This helps in building trust and reputation in the market, leading to increased customer loyalty and positive brand perception.
- What are the types of Halt and Hass chamber HAMCO makes :-
* Hamco has 3 different range of Halt and Hass Chamber
* 0 to 100 Deg C only Temp .
* -20 to 100 Deg C only Temp .
* -40 to +150 Deg C only Temp .
* Here we consider 1 Deg as Ramp Rate. If you need diffeent ramp rate than we have 3 deg C/ Minute to 5 Deg C/ Min Model available.
- What are other names Halt and Hass Chamber is Known.
- Halt and Hass Chamber
- Halt and Hass Test chamber
- Halt Chamber
- Hass chamber
- Halt hass testing equipment mumbai
- Why HAMCO ?
Ans:- Hamco has reach experience in designing and manufacturing Halt and Hass chamber since last 15 years. We are having more than 1000 successful installation in India and globe. We are strong service support with In house manufacturing and software design capabilities.
- Halt and Hass chamber manufacturer
- Halt and Hass chamber manufacturer in india
- Halt and Hass chamber supplier in india
- Halt and Hass chamber manufacturer in Mumbai
- Halt and Hass chamber india
- Hass testing chamber exporters
-
| CERTIFICATIONS
|
OUR CHAMBERS ARE CE Certified Chambers . We as company is ISO 9001:2008 Certified Company.
|
| FEATURES | Consist of Chamber (Hamco 46 series) + Ethernet Communication card + HMI (PLC 7) + SOFTW-21 (Web based Software Part 11 21 CFR ) +DS (Door Access System) + SAFETY-1 |
| RANGE/ HUMIDITY/ACCURACY / UNIFORMITY | Temperature Range -70C to 180C , Temperature Accuracy +/- 1C , Temperature Uniformity : +/- 2C .
Humidity Range 10 to 95% RH , Humidity accuracy +/- 3% RH, Humidity uniformity +/- 5% RH |
|
RAMP RATE |
Ramp Rate will be 5C / Minute Overall.
Here Optimum Heat load considered. Hamco Suggest “The buyer is required to provide the heat load specifications prior to placing the order to ensure accurate system design and performance.” |
|
CONSTRUCTION GMP MODEL |
Double walled , gap between walls filled with PUF Insulation. Inner Body made of SS 304 Mirror Finished, Outside SS 304 Matt finished. Double door : Inner full Viewing door and outer door insulated with lock and key arrangement. 50mm Validation Port with silicon rubber seal to insert sensor for validation purpose. 3 Thick CFC Free Puff Insulation. Stainless steel Trays. Adjustable Tray Height adjustment. Unit Mounted on castor wheels with front lock arrangement. Stainless steel Rod Trays. Adjustable Tray Height adjustment. |
| LIGHTING | Floroscent Light are provided , which automatically On when we open the door. |
|
CHAMBER PRINCIPLE |
Air circulation by Circulation Motor & Fan will continuously sucks the air from the chamber and Passes it through Air heater, Evaporator and through it back to chamber and same air will be recirculated to achieve desired Temperature stability inside chamber. Our design reduces the power consumption by 50% . |
|
ICH GUIDELINES |
Fully Suitable to carry out Stability Studies For Conditions Such As :
Only Temperature :- -70C -40C -20C -10C 0C 25C 50C 75C 100C 150C Temp & Humidity :- 25C / 60%RH 30C / 65%RH 30C / 75%RH 40C / 75%RH 25C /40%RH 30C / 35%RH 30C / 65%RH 40C / NMT 25%. 85C / 85%RH 60C / 95%RH 23C/50% RH Any Temperature & Humidity within Range of Temperature & Humidity. Other Than this cycle Please Mention it before order. |
|
PROGRAMMABLE FEATURES |
This is Multi set point programmable chamber where you can program chamber based on different temperature, its ramp time, soak time and particular out put on/off during the step.
We have 5 program we can make in this chamber. Each program can have 32 steps in it. Each program we can repeat 999 times. Hamco suggest “Kindly provide the detailed programmable cycle specifications prior to order to ensure proper configuration and testing of the heating and cooling chamber.” |
|
APPLICATIONS |
Application includes Electronics & Semiconductor, Aerospace, Pharmaceuticals , Automobile, Packing Medical Storage & R&D activity. |
|
HEATING , COOLING & HUMIDITY SYSTEM |
Heating system: U shaped Nichrome wire heater in SS Sheathing.
Hermetically sealed CFC free Emerson compressor with R 134a refrigerant for Positive Cycle . Cascade Cooling system : Hermetically sealed CFC free Emerson compressor with R 404 refrigerant for Negative Cycle a cascade compressor and Hermetically sealed CFC free Emerson compressor with R 23 refrigerant as Main compressor. Three compressor Only. Bypass solenoid valve for High temp application. Humidity generation by steam injection. Air circulation : Flange Motor with Impeller and blower. Interior Illumination for working Area. There will be two nos of blower from 450 Ltr Onwords. |
|
DQ,IQ,OQ,PQ |
To Help the customers to meet current regulatory requirements for the equipment , Hamco can provide DQ,IQ,OQ,PQ Protocols. This Protocol ensures that the system is properly installed, Operating as per our recommendations , Adequately documented and controlled according to regulatory requirements.
Calibration certificate & Test certificate of critical components along with Operation , Maintenance Manual, Wiring diagram , chamber diagram, sensor position diagram provided. Operation Training of the instruments along with software installation and software Training is part of our Operation Qualification.
|
|
VALIDATION & CALIBRATION |
Calibration of chamber is provided with Treacability against standard used.
–N.A.–Hamco will give one cycle 24 hours Validation report offsite . ( Validation is putting temp & RH sensors at different position in the chamber confirming Uniformity at different places in the chamber. )
|
| TEMPERATURE & HUMIDITY SENSOR | High Quality Temperature & Humidity Combo Sensor with 4-20 mA output with stable reading . Temperature resolution 0.1C and Humidity resolution 0.1%RH. |
|
DISPLAY |
HMI Display is 7 Color Touch Screen Display of Delta Make with display shows
set & Process Value of Temp & Humidity Active Alarm List Status of Component. Password Protected Display Alarm List & its History. Graph Display of Temperature & Humidity. Limited Door Access through Password Protection. Multi set point facility – Programmable controller which can set 32 Steps and 5 programmes in the memory. Total Repeat of cycle 999 Times. TS1 output which can be ON when during cyclic mode you want to turn on some output. This output can be programmable. Live graph facility to check the programme status
|
| DOOR ACCESS SYSTEM
(DS) |
Limited Door access through Password protection. The person with Authorised password can only open the door with reason . In software we get the door access report which shows who open the door , when & for what reason with time stamp. |
| BIOMETRIC DOOR ACCESS SYSTEM
(BDS) |
Thumb print door access system. Limited Door access through Finger print protection. The person with Authorised Finger print can only open the door with reason . In software we get the Biometric door access report which shows who open the door , when & for what reason with time stamp. |
| MOBILE ALERT (GSM) | —-N.A.——— ( Only in Premium Model , You will get SMS Alert on critical utility paramenters like Temp High & Low Alarm, Humidity High & Low Alarm, Low water Level, Power Fail etc. |
|
CONTROLLING SYSTEM |
The controlling system is Fully PLC Controller Based , It consist of 7 HMI PLC , OFFline Data logger with 10,000 Data Storage,Offline printer port suitable to dot-matrix printer , Relays, Contactors, Overload Trip devices, MCB.
IP 22 Protection. Data Storage of 10,000 Readings. If we set data interval of 30 Mins , it can save approx. one year data. Controls Temp using PID Loops. Ethernet Communication Port for PC Connectivity.
|
|
SAFETY |
Temperature Safety :-
When Temperature deviates higher side than their prescribed limits , the Heater will be cut off by Thermostate. Once it reach within the range , the heating system reset automatically. Humidity Safety :- When Humidity deviates higher side than their prescribed limits , the Boiler will be cut off by switchgears. It generated alarm and horn the buzzer if it deviates. Once it reach within the range , the Humidity system reset automatically. Low water level safety , In case of Insufficient water in boiler tank, the Boiler is Cut off and it generates the alarm and horn the buzzer . When it resumes, it starts automatically. Human Safety :- All the component has individual MCB for Overload and trip protection. The system has provided with proper earthing.
|
|
ALARM GENERATION |
Audio & Visual Alarms are generated for :
Temperature Deviation. Sensor Failure. Component Failure. Mains Failure. Door Open Thermostate High |
| PC COMMUNICATION | PC Interface communication Card with Ethernet Based connectivity. |
|
SOFTWARE 21 |
It is Web Based Software. Having Below said Features .
21 CFR Part 11 Requirements are Met. GMP Compliant- Tamper Proof Documentation of Measured data. Can Connect 20 Chambers at a Time. Authorised Access Only. Auto Backup Facility. Password Expiry & Multi Wrong attempt of Password will block the User. Auto Logout for no activity during Prescribed Time. Unlimited Users , Multiple login levels. Can Created Data Log Report & Alarm for Temp & RH. Scanner & Scanner Alarm Report for Temp & RH.
|
Ordering Information:-
Temp. Range: -70 to + 190 deg C, Humidity range: 10 to 95% RH
| Model No. | Capacity | Dimension In Cms | Shelves | Wt. In Kg | Power | |||||
| Standard | GMP | Cu. Ft | Ltr. | Chamber | Over All | Unit | Packed in wooden case | VAC Hz | Watts | |
| HAMCO46S-4(-70/T+Rh) | HAMCO46G-3(-70/T+Rh) | 4 | 120 | 45x45x60 | 65x95x180 | 2 | 150 | 225 | 230,50 | 3000 |
| HAMCO46S-8(-70/T+Rh) | HAMCO46G-8(-70/T+Rh) | 8 | 200 | 60x60x60 | 90x130x180 | 2 | 220 | 300 | 230,50 | 3500 |
| HAMCO46S-12(-70/T+Rh) | HAMCO46G-12(-70/T+Rh) | 12 | 324 | 60x60x90 | 90x130x210 | 3 | 230 | 320 | 230,50 | 4000 |
| HAMCO46S-16(-70/T+Rh) | HAMCO46G-16(-70/T+Rh) | 16 | 450 | 60x60x125 | 90x130x245 | 4 | 340 | 430 | 230,50 | 4500 |
| HAMCO46S-21(-70/T+Rh) | HAMCO46G-21(-70/T+Rh) | 21 | 600 | 60x80x125 | 90x150x245 | 5 | 365 | 465 | 230,50 | 5000 |
| HAMCO46S-28(-70/T+Rh) | HAMCO46G-28(-70/T+Rh) | 28 | 800 | 80x80x125 | 110x150x245 | 5 | 390 | 500 | 230,50 | 6000 |
| HAMCO46S-34(-70/T+Rh) | HAMCO46G-34(-70/T+Rh) | 34 | 1000 | 100x100x100 | 130x170x220 | 5 | 430 | 525 | 440,50 | 7000 |
| HAMCO46S-53(-70/T+Rh) | HAMCO46G-53(-70/T+Rh) | 53 | 1500 | 120X120X100 | 150X190X220 | 5 | 600 | 750 | 440,50 | 9000 |
| HAMCO46S-70(-70/T+Rh) | HAMCO46G-70(-70/T+Rh) | 70 | 2000 | 120X120X130 | 150X190X270 | 5 | 600 | 750 | 440,50 | 12000 |
- Option with 3 deg C / 5 deg C Model is available.
Temp. Range: -40 to + 150 deg C, Humidity range: 10 to 95% RH
| Model No. | Capacity | Dimension In Cms | Shelves | Wt. In Kg | Power | |||||
| Standard | GMP | Cu. Ft | Ltr. | Chamber | Over All | Unit | Packed in wooden case | VAC Hz | Watts | |
| HAMCO46S-4(-40/T+Rh) | HAMCO46G-3(-40/T+Rh) | 4 | 120 | 45x45x60 | 65x95x180 | 2 | 150 | 225 | 230,50 | 2500 |
| HAMCO46S-8(-40/T+Rh) | HAMCO46G-8(-40/T+Rh) | 8 | 200 | 60x60x60 | 80x130x180 | 2 | 220 | 300 | 230,50 | 3000 |
| HAMCO46S-12(-40/T+Rh) | HAMCO46G-12(-40/T+Rh) | 12 | 324 | 60x60x90 | 80x130x210 | 3 | 230 | 320 | 230,50 | 3500 |
| HAMCO46S-16(-40/T+Rh) | HAMCO46G-16(-40/T+Rh) | 16 | 450 | 60x60x125 | 80x130x245 | 4 | 340 | 430 | 230,50 | 4000 |
| HAMCO46S-21(-40/T+Rh) | HAMCO46G-21(-40/T+Rh) | 21 | 600 | 60x80x125 | 80x150x245 | 5 | 365 | 465 | 230,50 | 4500 |
| HAMCO46S-28(-40/T+Rh) | HAMCO46G-28(-40/T+Rh) | 28 | 800 | 80x80x125 | 100x150x245 | 5 | 390 | 500 | 230,50 | 5000 |
| HAMCO46S-34(-40/T+Rh) | HAMCO46G-34(-40/T+Rh) | 34 | 1000 | 100x100x100 | 120x170x220 | 5 | 430 | 525 | 440,50 | 6000 |
| HAMCO46S-53(-40/T+Rh) | HAMCO46G-53(-40/T+Rh) | 53 | 1500 | 120X120X100 | 140X190X220 | 5 | 600 | 750 | 440,50 | 7000 |
| HAMCO46S-70(-40/T+Rh) | HAMCO46G-70(-40/T+Rh) | 70 | 2000 | 120X120X130 | 140X190X270 | 5 | 600 | 750 | 440,50 | 9000 |
- Option with 3 deg C / 5 deg C Model is available.
Temp. Range: -20 to + 100 deg C, Humidity range: 25 to 95% RH
| Model No. | Capacity | Dimension In Cms | Shelves | Wt. In Kg | Power | |||||
| Standard | GMP | Cu. Ft | Litres | Chamber | Over All | Unit | Packed in wooden case | VAC Hz | Watts | |
| HAMCO46S -3(-20/T+Rh) | HAMCO46G-3(-20/T+Rh) | 3 | 90 | 45x45x45 | 60x95x110 | 2 | 110 | 165 | 230,50 | 1500 |
| HAMCO46S-4(-20/T+Rh) | HAMCO46G-3(-20/T+Rh) | 4 | 120 | 45x45x60 | 60x95x125 | 2 | 150 | 225 | 230,50 | 2000 |
| HAMCO46S-8(-20/T+Rh) | HAMCO46G-8(-20/T+Rh) | 8 | 200 | 60x60x60 | 80x110x125 | 2 | 220 | 300 | 230,50 | 2500 |
| HAMCO46S-12(-20/T+Rh) | HAMCO46G-12(-20/T+Rh) | 12 | 324 | 60x60x90 | 80x110x155 | 3 | 230 | 320 | 230,50 | 2500 |
| HAMCO46S-16(-20/T+Rh) | HAMCO46G-16(-20/T+Rh) | 16 | 450 | 60x60x125 | 80x130x175 | 4 | 340 | 430 | 230,50 | 4000 |
| HAMCO46S-21(-20/T+Rh) | HAMCO46G-21(-20/T+Rh) | 21 | 600 | 60x80x125 | 80x130x195 | 5 | 365 | 465 | 230,50 | 4000 |
| HAMCO46S-28(-20/T+Rh) | HAMCO46G-28(-20/T+Rh) | 28 | 800 | 80x80x125 | 100x130x210 | 5 | 390 | 500 | 230,50 | 4500 |
| HAMCO46S-34(-20/T+Rh) | HAMCO46G-34(-20/T+Rh) | 34 | 1000 | 80x80x155 | 100x130x220 | 5 | 430 | 525 | 230,50 | 4500 |
Temp. Range: 0 to + 100 deg C, Humidity range: 25 to 95% RH
| Model No. | Capacity | Dimension In Cms | Shelves | Wt. In Kg | Power | |||||
| Standard | GMP | Cu. Ft | Litres | Chamber | Over All | Unit | Packed in wooden case | VAC Hz | Watts | |
| HAMCO46S -3(0/T+Rh) | HAMCO46G-3(0/T+Rh) | 3 | 90 | 45x45x45 | 60x95x110 | 2 | 110 | 165 | 230,50 | 1500 |
| HAMCO46S-4(0/T+Rh) | HAMCO46G-3(0/T+Rh) | 4 | 120 | 45x45x60 | 60x95x125 | 2 | 150 | 225 | 230,50 | 2000 |
| HAMCO46S-8(0/T+Rh) | HAMCO46G-8(0/T+Rh) | 8 | 200 | 60x60x60 | 80x110x125 | 2 | 220 | 300 | 230,50 | 2500 |
| HAMCO46S-12(0/T+Rh) | HAMCO46G-12(0/T+Rh) | 12 | 324 | 60x60x90 | 80x110x155 | 3 | 230 | 320 | 230,50 | 2500 |
| HAMCO46S-16(0/T+Rh) | HAMCO46G-16(0/T+Rh) | 16 | 450 | 60x60x125 | 80x130x175 | 4 | 340 | 430 | 230,50 | 4000 |
| HAMCO46S-21(0/T+Rh) | HAMCO46G-21(0/T+Rh) | 21 | 600 | 60x80x125 | 80x130x195 | 5 | 365 | 465 | 230,50 | 4000 |
| HAMCO46S-28(0/T+Rh) | HAMCO46G-28(0/T+Rh) | 28 | 800 | 80x80x125 | 100x130x210 | 5 | 390 | 500 | 230,50 | 4500 |
| HAMCO46S-34(0/T+Rh) | HAMCO46G-34(0/T+Rh) | 34 | 1000 | 80x80x155 | 100x130x220 | 5 | 430 | 525 | 230,50 | 4500 |