Automatic Isoperibol Bomb Calorimeter
HAMCO6F Automatic Isoperibol Bomb Calorimeter With PLC With Printer As Per Astm D 5865
WITH EXTERNAL CHILLER AND 2000ML AUTO BURRETTE
- What is ISOPERBOL Bomb calorimeter.
The term “isoperibol” means constant pressure. In an isoperibol calorimeter, the bomb is submerged in a known volume of water, and the whole system is enclosed in an insulated container. The water acts as a heat sink, absorbing the heat released during the combustion reaction. Insulated container which normally contain highly precision temperature water which act as insulator from the surrounding and this constant temperature water makes the system more accurate.
- Benefits of using Hamco 6F( Automatic Isoperibol Bomb Calorimeter) over Hamco 6E
- Much More accurate results :- As in Isoperibol method due to high precision of the jacket water and same water will be used as bucket makes it much more accurate and isolate from room temperature fluctuation.
- Easier Calibration :- Isoperibol calorimeters are generally easier to calibrate compared to isothermal calorimeters. The water jacket surrounding the bomb helps in stabilizing the temperature and pressure conditions, simplifying the calibration process and ensuring more consistent results. The duration of calibration is much higher compared to isothermal bomb calorimeter. Normally frequency to calibrate isoperibol bomb calorimeter is around 3 to 4 months.
- Reduced Heat Loss: The insulated design of the isoperibol calorimeter minimizes heat loss to the surroundings during the combustion process. This insulation helps maintain the accuracy of temperature measurements and reduces errors that could arise from external temperature fluctuations.
- More Accurate Heat Measurements: By maintaining constant pressure conditions and minimizing heat loss, isoperibol calorimeters generally provide more accurate measurements of the heat of combustion compared to isothermal calorimeters. This accuracy is crucial in research and industrial applications where precise energy content determination is essential.
- Why HAMCO Make Automatic Isoperibol Bomb calorimeter ?
- Hamco has more than decade experience in manufacturing of automatic isoperibol bomb calorimeter.
- Hamco has successfully delivered and commissioned more than 1000 automatic Bomb calorimeter in India and across the globe.
- Hamco is constantly Innovating and bring best of best technology and feature first in the market which allows our customers to win.
- Hamco is one of the leading manufacturer of Automatic isoperibol bomb calorimeter in india.
- Hamco is Manufacturer of Precise Automatic bomb calorimeter manufacturer in india.
BOMB CALORIMETER DETAILS | |||
SR.NO | PARAMETER | M/s Hindustan apparatus, Mumbai , Model HAMCO-6E | M/s Hindustan apparatus, Mumbai , Model HAMCO-6F |
1 | Type of bomb Calorimeter | FULLY AUTOMATIC PLC BASED | FULLY AUTOMATIC PLC BASED WITH EXTERNAL CHILLER AND SEMIAUTO WATER FILLING |
2 | METHOD | AUTOMATIC ISOTHERMAL BOMB CALORIMETER | AUTOMATIC ISOPERIBOL BOMB CALORIMETER |
3 | Measuring principal and method | ISOTHERMAL AND ASTM D4893,240,5865 | ISOPERIBOL AND ASTM D4893240,5865 |
4 | GCV Capacity ( range) | 1000 TO 20000 KILO CALORY P/KGM | 500 TO 20000 KILO CALORY P/KGM |
5 | Testing precision( precision mode) | 1% RSD ON BENZOIC ACID STANDARD SAMPLE | 0.1% RSD ON BENZOIC ACID STANDARD SAMPLE |
6 | Testing precision(predictive mode) | 1% RSD | 0.1% RSD |
7 | Resolution of GCV | 1 CALORIE PER GRAM | 0.1 CALORIE PER GRAM |
8 | Nos of Analysis per Hour | MAXIMUM 4 | MAXIMUM 4 TO 6 |
9 | Analysis Time | 10 TO 15 MIN | 10 TO 12 MIN |
10 | Temp. Measurement Accuracy | 0.0001 Deg C | 0.0001 Deg C |
11 | Temp. Measurement Resolution | 0.0001 Deg C | 0.0001 Deg C |
12 | Permisible Value Ambient Temp. | 15 to 40 Deg C | 15 to 40 Deg C |
13 | Gas (Oxygen)Filling | AUTO | AUTOMATIC |
14 | Bomb washing | MANUAL | MANUAL |
15 | Bucket filling | MANUAL | SEMIAUTOMATIC WITH MEASURE BURETTE |
16 | Wire tying | MANUAL | MANUAL |
17 | Bomb pressure release | AUTOMATIC | AUTOMATIC |
18 | Water circulation in outer jacket | PUFF INSULATED | WATER JACKETING AUTOMATIC WITH EXTERNAL CHILLER WITH ACCURACY OF +/- 0.05 DEG C |
19 | Digital Weighing Scale For Auto Weight Transfer by Softwire | MANUAL ENTRY | SUITABLE TO MATLER OR MANUAL ENTRY |
20 | Software | WEB BASED SOFTWARE WITH ONLINE AND OFFLINE MONITORY | WEB BASED SOFTWARE WITH ONLINE AND OFFLINE MONITORY |
21 | Report Customization | NOT POSSIBLE | POSSIBLE WITH SOFTWARE ONLY |
22 | Computer Requirement | YES AT BUYSER SCOPE | YES AT BUYSER SCOPE |
23 | Installation & commissioning | YES REQUIRED | YES REQUIRED |
24 | Accessories | 500 Samples | 2000 Samples |
25 | Power consumption per hrs use | 2 UNITS PER DAY MAXIMUM | 2 UNITS PER DAY MAXIMUM |
26 | Room Temperature | NEED AC OR CONTROLLED ROOM TEMP | NOT REQUIRED |
27 | Chiller | NOT INCLUDED | INCLUDED |
28 | Coal sample preparation Kit | NOT INCLUDED | INCLUDED |